Showing results: 181 - 195 of 502 items found.
-
MA 2112/D/H/S-7/GR228x-15/7 -
INGUN Prüfmittelbau GmbH
Parallel contact stroke: 15 mmContact force max.: 2000 NInterface block required: Test system sideInterface signals max.: 1190Component on PCB: 58 mmPressure frame unit-opening angle: 75Installation height test probe top: 16,0 mmInstallation height test probe bottom: 10,5 mmInstallation height dual-stage test probe bottom: 16,0 mmweight: 17,30 kg
-
MA 2112/D/H/S-7/GR228x-15/15 -
INGUN Prüfmittelbau GmbH
Parallel contact stroke: 15 mmContact force max.: 2000 NInterface block required: Test system sideInterface signals max.: 1190Component on PCB: 58 mmPressure frame unit-opening angle: 75Installation height test probe top: 16,0 mmInstallation height test probe bottom: 10,5 mmInstallation height dual-stage test probe bottom: 16,0 mmweight: 17,46 kg
-
MA 2111/D/H/S-5/HG -
INGUN Prüfmittelbau GmbH
Parallel contact stroke: 15 mmContact force max.: 2000 NInterface block required: Test system sideInterface signals max.: 850Component on PCB: 58 mmPressure frame unit-opening angle: 75Installation height test probe top: 16,0 mmInstallation height test probe bottom: 10,5 mmInstallation height dual-stage test probe bottom: 16,0 mmweight: 10,70 kg
-
MA 2112/D/H/S-7/HG/KT-ITA-21 -
INGUN Prüfmittelbau GmbH
Parallel contact stroke: 15 mmContact force max.: 2000 NInterface block required: Test system sideInterface signals max.: 1190Component on PCB: 58 mmPressure frame unit-opening angle: 75Installation height test probe top: 16,0 mmInstallation height test probe bottom: 10,5 mmInstallation height dual-stage test probe bottom: 16,0 mmweight: 16,30 kg
-
MA 2109/D/H/S-5 -
INGUN Prüfmittelbau GmbH
Parallel contact stroke: 15 mmContact force max.: 2000 NInterface block required: Test system sideInterface signals max.: 850Component on PCB: 58 mmPressure frame unit-opening angle: 75Installation height test probe top: 16,0 mmInstallation height test probe bottom: 10,5 mmInstallation height dual-stage test probe bottom: 16,0 mmweight: 8,50 kg
-
MA 2112/D/H/S-7/GR2270/71 -
INGUN Prüfmittelbau GmbH
Parallel contact stroke: 15 mmContact force max.: 2000 NInterface block required: Test system sideInterface signals max.: 1190Component on PCB: 58 mmPressure frame unit-opening angle: 75Installation height test probe top: 16,0 mmInstallation height test probe bottom: 10,5 mmInstallation height dual-stage test probe bottom: 16,0 mmweight: 12,13 kg
-
RF100 -
Laplace Instruments Ltd.
The RF100 probe set consists of a passive E field probe and H field probe, BNC adaptor and carry case. The output is via a BNC socket. These are general purpose probes which are ideal for use in conjunction with an EMC measuring system. They are sensitive to sources in close proximity, but are insensitive to background signals. This makes them ideal for the identification of emission frequencies in noisy environments... thus making measurements easier and quicker. The proximity requirement also enables sources to be located and the exit route identified.
-
IT Concepts llc
Documentation Unit + High Power Light Source + probe incl. Control and lens The modular systems can be combined and endlessly expandable.
-
Multigauge 5600 -
Tritex
On screen user information such as probe frequency and remaining battery. Colour LCD display. Easy to use keypad and menu system.
-
Jandel Engineering Limited
Jandel probe heads are manufactured solely by Jandel Engineering Limited and there is one to fit all mountings and systems known to us.
-
UF3000EX-e -
CSE Co.,Ltd
Wafer Probe Station is used in connection with test system in Wafer Test process.It is a device to move wafer automatically to examine fair quality of individual chip on the wafer. Probe Station is seperated depending on purpose. For analysis, for mass production as well as manual, semi-automatic, full-automatic.
-
L2.92A-PBUS -
Teledyne LeCroy
The Teledyne LeCroy LabMaster 10 Zi oscilloscope utilizes precision 2.92mm input connectors to achieve up to 36GHz of input bandwidth. But some applications may require the use of lower-bandwidth probes for performance and cost reasons.The L2.92A-PBUS adapter converts the 2.92mm interface to a ProBus interface. This brings the benefits of a wider selection of probes to the LabMaster 10 Zi from high-impedance ZS active probes to the high-bandwidth WaveLink differential probing system. Full probe power and control is provided through a built-in LEMO interface.
-
ICR E150 -
Langer EMV-Technik GmbH
The near field microprobe is used to measure electric fields at extremely high resolution and sensitivity. The optimal distance to the object being measured is < 1 mm. Due to its small probe head dimension, the probe has to be moved by a manual or automatic positioning system, e.g. Langer-Scanner.
-
DP0010A -
Keysight Technologies
The Keysight DP0010A is the 250 MHz model of the DP001xA Series differential active probes. These probes provide the superior general-purpose differential signal measurements required for many of today’s high-speed power-related measurements such as motor drives, automotive differential bus measurements, and high-speed digital system designs.
-
DP0011A -
Keysight Technologies
The Keysight DP0011A is the 500 MHz model of the DP001xA Series differential active probes. These probes provide the superior general-purpose differential signal measurements required for many of today’s high-speed power-related measurements such as motor drives, automotive differential bus measurements, and high-speed digital system designs.